Case studies
Co-op towing
Organization
Co-op Towing
Toronto, Canada
Equipment
Diesel engine on GMC Topkick
Objective
To improve filtration by the removal of ferrous particles out of the oil system of a diesel engine with a magnetic
filtration system (Halex Coil). An oil sample was taken at end of
an oil cycle. In this case, oil was changed at 830 km. After the
initial sample was taken, the Halex Coil was installed. At 12853 km,
a second oil sample was taken.
Scan of the lab results (496 KB
)
| Unit data |
| Sample # |
Date sampled |
Component km |
Oil km |
Oil change |
|
| ###### |
02/01/95 |
12853.0 |
0.0 |
no |
| ###### |
01/10/95 |
830.0 |
9987.0 |
yes |
|
| Spectrographic analysis (ppm) |
| Sample # |
Al Aluminum |
Cr Chromium |
Cu Copper |
Fe Iron |
Sn Tin |
Pb Lead |
Si Silicon |
Mo Molybdenum |
Ni Nickel |
Ag Silver |
|
| ###### |
6 |
1 |
8 |
13 |
0 |
0 |
9 |
0 |
0 |
0 |
| ###### |
15 |
2 |
37 |
41 |
0 |
6 |
14 |
0 |
0 |
0 |
|
| Spectrographic analysis (ppm) |
| Sample # |
K Potassium |
Na Sodium |
B Boron |
Ba Barium |
Ca Calcium |
Mg Magnesium |
Mn Manganese |
P Phosphorus |
Zn Zinc |
|
| ###### |
0 |
14 |
154 |
2 |
713 |
954 |
0 |
1090 |
1193 |
| ###### |
0 |
12 |
158 |
22 |
2396 |
596 |
5 |
1063 |
1262 |
|
| Physical properties |
| Sample # |
Glycol |
H2O |
% Fuel |
Viscocity 40 °C |
Viscocity 100 °C |
% Solids |
|
| ###### |
no |
no |
0.0 |
93.1 |
12.9 |
0.0 |
| ###### |
no |
no |
0.0 |
62.6 |
9.7 |
0.0 |
|
| Wear control chart |
| 0 |
20 |
40 |
60 |
80 |
100 |
120 |
140 |
|
|
37 |
|
115 |
|