Case studies

Faster linen

Organization
Faster Linen Service Ltd.
89 Torlake Crescent
Toronto, ON  M8Z 1B4
Equipment

Diesel engine on GMC 350

Objective

To improve filtration by the removal of ferrous particles out of the oil system of a diesel engine with a magnetic filtration system (Halex Coil).  An oil sample was taken at end of an oil cycle.  In this case, oil is changed at 3604 km.  After the initial sample was taken, the Halex Coil was installed.  At 4817 km, a second oil sample was taken.

Sacn of the lab results and correspondence with Faster Linen (763 KB PDF file)

Unit data
Sample # Date
sampled
Component
km
Oil
km
Oil
change
149644 02/01/95 4847.0 0.0 no
149673 01/18/95 3604.0 0.0 yes
Spectrographic analysis (ppm)
Sample # Al
Aluminum
Cr
Chromium
Cu
Copper
Fe
Iron
Sn
Tin
Pb
Lead
Si
Silicon
Mo
Molybdenum
Ni
Nickel
Ag
Silver
149644 5 0 27 38 5 16 51 0 0 0
149673 7 2 100 135 13 76 200 8 0 0
Spectrographic analysis (ppm)
Sample # K
Potassium
Na
Sodium
B
Boron
Ba
Barium
Ca
Calcium
Mg
Magnesium
Mn
Manganese
P
Phosphorus
Zn
Zinc
149644 0 65 106 0 1939 148 41 985 1228
149673 0 298 10 1 1138 547 59 1068 1360
Physical properties
Sample # Glycol H2O %
Fuel
Viscocity
40 °C
Viscocity
100 °C
%
Solids
149644 no no 0.0 97.6 13.6 0.0
149673 no no 0.0 66.4 12.1 0.0
Wear control chart
0 80 160 240 320 400 480 560
142
533
back to top