Case studies

Kittery public works

Organization
Kittery Public Works
200 Rogers Road Extension
Kittery, ME  03904
Equipment

Engine on 1994 Volvo

Objective

To improve filtration by the removal of ferrous particles out of the oil system with a magnetic filtration system (Halex Coil).  An oil sample was taken at end of an oil cycle.  After the initial sample was taken, the Halex Coil was installed.

Scan of the lab results (556 KB PDF file)

Unit data
Sample # Date
sampled
Component
km
Oil
km
Oil
change
###### 07/06/95 19000.0 5000.0 yes
###### 04/07/95 14000.0 6000.0 yes
###### 03/06/95 0.0 8000.0 yes
Spectrographic analysis (ppm)
Sample # Al
Aluminum
Cr
Chromium
Cu
Copper
Fe
Iron
Sn
Tin
Pb
Lead
Si
Silicon
Mo
Molybdenum
Ni
Nickel
Ag
Silver
###### 3 0 9 29 0 4 11 5 0 0
###### 3 0 10 40 0 5 15 5 0 0
###### 3 0 8 64 0 5 12 9 0 0
Spectrographic analysis (ppm)
Sample # K
Potassium
Na
Sodium
B
Boron
Ba
Barium
Ca
Calcium
Mg
Magnesium
Mn
Manganese
P
Phosphorus
Zn
Zinc
###### 4 581 1 0 766 574 78 1002 1126
###### 0 604 2 2 799 606 113 1043 1168
###### 0 512 3 2 756 555 155 981 1108
Physical properties
Sample # Glycol H2O %
Fuel
Viscocity
40 °C
Viscocity
100 °C
%
Solids
###### no no 0.0 41.5 7.6 0.0
###### no no 0.0 39.0 7.7 0.0
###### no no 0.0 42.4 7.8 0.0
Wear control chart
0 25 50 75 100 125 150
56
73
92
back to top