Case studies

Waste management

Organization
Waste Management
26 Liberty Drive
Londonderry, NH  03053
Equipment

Gasoline engine on GMC 5.7 L #610

Objective

To improve filtration by the removal of ferrous particles out of the oil system of a gasoline engine with a magnetic filtration system (Halex Coil).  An oil sample was taken at end of an oil cycle.  In this case, oil is changed every 300 hr.  After the initial sample was taken, the Halex Coil was installed.  At the next 300 hr, a second oil sample was taken.  This was a dynamic test.

Scan of the lab results (750 KB PDF file)

Unit data
Lab
No.
Date
sampled
Mi/hr
unit
Mi/hr
oil
Oil
changed
942277 08/14/95 6318 260 C
908214 05/10/95 6058 300 C
887055 03/16/95 5873 300 C
Physical properties
Lab
No.
Viscosity (cSt)
@ 100 °C
Viscosity
grade
Water
% Vol.
Insolubles
(soot)
% Wt.
Fuel
% Vol.
Glycol
(anti-freeze)
942277 19.10 50 Neg <0.1 Neg
908214 20.90 50 Neg <0.1 Neg
887055 35.40 60 Neg <0.1 Neg
Spectrographic analysis
Lab
No.
Silicon
(dirt)
Iron Chromium Aluminum Tin Copper Lead Nickel Molybdenum
942277 19 53 2 8 3 8 34 <1 7
908214 19 77 2 10 1 9 42 <1 7
887055 35 270 6 31 8 19 86 <1 22
back to top